Delay profile:
The delay profile is an airflow profile that the system will run in COOL mode. These profiles are not
implemented in heating. Each profile is designed to accommodate the original environment where
the equipment is installed.
Airflow Config
11:07AM Thu 21 Jul
Dry
Delay Profile: Dry
Best in dry regions such as the southwest
Temperate
US.
Increases the blower ramp-down times to
Humid
help retain humidity.
Normal
Airflow Summary
Airflow Summary 11:07AM Thu 21 Jul
809
Heat Pump
Model YZH036
809
Set CFM
530
730
Air Handler
AH Model AV060
Heat Kit Model 4HKx6501506
Airflow Configuration
Airflow Config
AH Airflow Config 11:07AM Thu 21 Jul
High Cool
High Cool
CFM: 1245
Restore Defaults
Min 400
View/Edit Dehumidification
The "View/Edit Dehum" check box, when selected, will display the option to reduce the airflow by a
selectable percentage when there is a call to dehumidify.
When changing airflow settings on electric heating components, the user should reference mini-
mum CFM values required for operation (provided in the communicating air handler installation
instructions).
28
Back
Next
Low Cool
1245
High Cool
Low Heat
1245
High Heat
1950
4.3 KW
4.8 KW
9.6 KW
1860
14.4 KW
Back
Next
Low Cool
High Heat
Low Heat
1245
Max 1800
Back
To change the delay profiles press the box next
to the profile that is desired (as pictured). Each of
the profiles, (when selected) will provide a brief
description of the profile design intent.
The airflow summary screen displays all current
airflow settings at a glance. To edit the airflow
settings press the indoor or outdoor button (heat
pump or air handler shown).
The airflow configuration screen shows the avail-
able airflow adjustments at the top of the screen
(High Cool, Low Cool, High Heat, etc.). Simply
press the desired adjustment to edit airflow.
Once in the desired airflow adjustment screen
the user can adjust the airflow by CFM (in 10
CFM increments) by sliding the "homeplate" icon
or pressing the "+" or "-" symbols.
The "Restore Defaults" button will return the
airflow to the factory setting.