Mains Electricity Connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY
BY A COMPETENT PERSON, USING FIXED WIRING VIA A
DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED
BY A 3A FUSE.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C. and
who will comply
with the I.E.T. and local regulations.
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
Green & Yellow = Earth, Blue = Neutral, Brown = Live.
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
connecting to the fuse spur, proceed as follows:
The wire which is coloured green and yellow must be connected to
the terminal marked E (Earth) or coloured green.
The wire which is coloured blue must be connected to the terminal
marked N (Neutral), or coloured black.
The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured red.
Note: Use a 3A Fuse
10
DOUBLE POLE SWITCHED
FUSE SPUR OUTLET
USE A 3 AMP FUSE