Room Thermostat Control - About Room Thermostat Control - Daikin Intergas Altherma Hybrid User Reference Manual

Hydrosplit heat pump
Table of Contents

Advertisement

4.4.4 Room thermostat control - About room thermostat control

EJHA04AAV3 + NHY2KOMB28+32AA
Daikin Altherma Hybrid hydrosplit heat pump
4P556862-1A – 2020.10
If...
Thermostat main A is
listed under:
[6.5]:
> Information
> Actuators
Else
2 Only for room thermostat control: Go to the main leaving water temperature
home page (LWT main) and check the following:
Is displayed next to
the set point?
Yes
No
Room thermostat control means that you control the following:
Room temperature of the main zone
Leaving water temperature of the main zone
Room temperature of the main zone
To control the room temperature of the main zone, you can do the following:
You can...
Read out the actual and desired room temperature.
Temporarily overrule the room temperature
schedule.
Change the mode from scheduled to preset value.
If you do this, you also have to define (in the menu
structure):
Preset values
Overrule period (Temperature lock)
Select which room temperature schedule you want to
use.
Program schedules.
Define preset values that are used by the room
temperature schedule, and when you change the
mode from scheduled to preset value.
See also:
"Room thermostat control - Using the room temperature home
"To set the overrule
period" [
"4.7 Preset values and
Then the temperature control is...
External room thermostat control.
Leaving water temperature control.
Then leaving water set point and room
temperature set point are...
NOT linked.
You can set the leaving water set point on the home
page.
Linked by their preset values. You can set the preset
values in the menu structure.
4
 20]
schedules" [
4
 37]
4
Operation
|
Main zone
Location
Room temperature home
page
Room temperature home
page if user profile =
Detailed
Menu structure
4
pages" [
 18]
User reference guide
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ejha04aav3Nhy2komb28aaNhy2komb32aa