Panasonic EP3203-U1 Service Manual page 11

Table of Contents

Advertisement

Adjustment of pressure sensor
First, keep the Massage mechanism block unloaded with pressure and move it
upward halfway.
If the Massage mechanism block is at the highest or lowest position, you cannot
arrange the pressure sensor correctly because the fabric becomes tense with
pressure.
1. While pushing On/off button and the User program button B simultaneously, turn
on the power switch and continue to hold the buttons for approximately 5
seconds. Release after the Focus button lights up.
2. Push the Focus button and automatically it lights off.
Turn off the Power source switch and turn it on again, then the adjustment is
finished.
Total use time & Display method
While pushing the Shiatsu button and the Deep button simultaneously, turn on the
power switch and continue to hold the buttons for approximately 5 seconds.
Release after the User program button A.
e.g. In the above case, 3000 + 500 + 10 + 5 = 3515 hours.