CrimeStopper SP-502 Installation Handbook page 21

Alarm combo system
Table of Contents

Advertisement

1. Engine R.P.M. (Tach) - Most reliable method. Tach must be programmed for this option to work.
2. Tachless Mode - Default. When vehicle is remote started, the battery voltage rate will go up because the
Alternator starts working. The Tachless Mode is adjustable in 1% increments thru Option 21.
3. Blank – No Function
4. Hybrid Mode – For vehicles that have a computer controlled starter. This provides a 4 second crank output to
activate the start sequence on Hybrid vehicle. Don't use on vehicles with gas or diesel engine, doesn't monitor
engine running or low battery voltage. Option #21 allows you to shorten starter crank time if necessary.
2. PINK / WHITE WIRE SELECTION:
This option controls the High Current Pink / White wire function.
1. Pink / White = Accessory 2
2. Pink / White = Ignition 2 - Default.
3. Pink / White = Start 2
3. PASSIVE ARMING:
This option is used to automatic arm the alarm system 30 seconds after the ignition is tuned off and the last door is
closed. If a door is reopened during the 30 second countdown, the system will wait and begin the countdown again
after the door is closed. There are 3 choices:
1. Passive Arm with Lock – The system Locks the doors with Passive Arm. This choice is best for security but
increases the risk of locking the keys in the ignition.
2. OFF = Default – No Passive Arming.
3. Passive Arm without Lock – The system Passive Arms without locking the doors.
4. ACTIVE REARM / AUTO REARM:
The option controls whether the alarm system rearms 30 seconds after disarm. This is handy if the vehicle is
accidentally disarmed without your knowledge. There are 4 choices:
1. Active Rearm ON – The system will Rearm and lock the doors unless the door, hood or trunk is opened.
2. OFF = Default - No Automatic Rearm in Passive or Active Mode.
3. Auto Rearm with Lock - The alarm system will always rearm and lock the doors after disarm unless the ignition
is turned on. This applies to Passive and Active Mode. This choice is best for security but increases the risk of
locking the keys in the ignition.
4. Auto Rearm without Lock - The alarm system will always rearm without locking the doors after disarm unless
the ignition is turned on. This applies to Passive and Active Mode.
PROGRAMMABLE OPTIONS
21