Heat Pump Control Unit Power Supply 230 V; Outdoor Unit Power Supply 230 V~/400 V - Viessmann Vitocal 200-S Installation And Service Instructions For Contractors

Air/water heat pump, split version for heating and cooling operation
Table of Contents

Advertisement

Installation sequence
Power supply
(cont.)
The assignment of the power-OFF (for compressor
and/or instantaneous heating water heater) is made
via the type of connection and by setting parameters
in the heat pump control unit.
In Germany, the power supply can be cut for a maxi-
mum of 3 x 2 hours per day (24 h).
The heat pump control unit/PCB must be supplied
without power-OFF. Tariffs subject to possible shut-
down must not be used here.
When using power generated on site (use of power
generated by the PV system to meet own require-
ments):
During the power-OFF period, it is not possible to
operate the compressor utilising power generated on
site.

Heat pump control unit power supply 230 V~

1/N/PE
230 V/50 Hz
A
F1 T6,3 AH
L1
L1
?
?
N
X40
Fig. 32

Outdoor unit power supply 230 V~/400 V~

Economy tariff and power-OFF can be used.
No parameters need to be set when using economy
tariff with power-OFF. The compressor is shut down
during the power-OFF period.
During power-OFF, the diagnostic functions for the
external unit are not supported.
Outdoor unit power supply 230 V~
Type AWB/AWB-E/AWB-AC
201.B04
C N L ?
A
N
L1
?
B
Fig. 33
36
N
201.B05/B07
Ni
?
COM
Fig. 34
Protect the power cable to the heat pump control unit
with an MCB/fuse of max. 16 A.
For accessories and external components that will
not be connected to the heat pump control unit, pro-
vide the power supply via the same MCB/fuse, or at
least on the same phase, as the heat pump control
unit.
Connection to the same MCB/fuse provides addi-
tional safety when the power is switched off.
Observe the power consumption of the connected
consumers.
The PE wire of the power cable must be approx.
10 mm longer than the N and L wires.
Note
This supply must never be blocked.
Max. fuse rating 16 A
Standard tariff (no optional economy tariff with
power-OFF facility)
Recommended power cable: 3 x 1.5 mm
(5 x 1.5 mm
2
with power-OFF)
Note
Free terminals for internal use.
Li
N
L
?
0
0
A
? N L1
B
2
201.B10/B13
C2 C1
N L
? N L
?
A
? N L1
B
Fig. 35

Hide quick links: