Heat Pump Control Unit Power Supply 230 V; Compressor Power Supply (400 V~), Sealing Economy Tariff Connection For Compressor - Viessmann Vitocal 350-A AWHO 351.A Series Installation And Service Instructions Manual

Air/water heat pump with electric drive
Table of Contents

Advertisement

Power supply
(cont.)

Heat pump control unit power supply 230 V~

A
max.16 A
X3.18
L1
1/N/PE
X2.1
N
230 V/50 Hz
X1.1
?
Fig. 55
A
Mains terminals inside the heat pump control unit
Note
This supply must never be blocked.

Compressor power supply (400 V~), sealing economy tariff connection for compressor

1.
Fig. 56
2.
3.
Max. fuse rating 16 A
Standard tariff: No economy tariff with power-OFF
possible for the heat pump control unit
Recommended power cable:
3 x 1.5 mm
2
Recommended power cable with power-OFF for
compressor/instantaneous heating water heater:
2
5 x 1.5 mm
1. Undo screws on contact shield
2. Route 400 V~ power cable through cable fitting
and apply strain relief.
Installation sequence
.
C
B
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitocal 350-a awhi 351.a10Vitocal 350-a awhi 351.a14Vitocal 350-a awhi 351.a seriesVitocal 350-a awho 351.a10Vitocal 350-a awho 351.a14Vitocal 350-a awho 351.a20 ... Show all