DHW heating
Operating programs
"PROGRAM" operating program
As with the "AUTO" operating program, but DHW is
heated during the time phases set in the time program;
see page 15.
DHW heating enabled
Outside temperature from –5 °C to +35 °C
0
DHW temperature in °C
Fig. 14
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
Standard DHW temperature ("AUTO")
D
DHW heating not enabled
Note
The immersion heater is only switched on for frost pro-
tection.
Outside temperature from –5 °C to +35 °C
0
10
DHW temperature in °C
Fig. 16
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
Standard DHW temperature ("PROG")
D
"NIGHT" operating program
As with the "AUTO" operating program, but DHW is
heated between 23:00 and 5:00. The start of DHW
heating is selected so that the standard DHW tempera-
ture is reached at 5:00.
14
(cont.)
Outside temperature below –5 °C or above +35 °C
0
DHW temperature in °C
Fig. 15
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
Standard DHW temperature ("AUTO")
D
Outside temperature below –5 °C or above +35 °C
0
10
DHW temperature in °C
Fig. 17
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
Standard DHW temperature ("PROG")
D
The immersion heater is switched on if the heat pump
cannot reach the standard DHW temperature.