Setting Operating Programs; Application Limits; Eco" Operating Program - Viessmann VITOCAL 060-A Operating Instructions For The System User

Dhw heat pump with immersion heater ehe
Table of Contents

Advertisement

Operating programs

Setting operating programs

Use
to select the required operating program.

Application limits

Note
The heat pump only switches on at outside tempera-
tures between –5 and 35 °C.
Outside this range, the immersion heater may be acti-
vated.
Example: Heat pump in outdoor air mode
70
62
60
50
40
30
-5
0
Air intake temperature in °C
Fig. 3
DHW temperature achievable with the heat pump:
A
62 °C

"ECO" operating program

DHW is only heated by the heat pump and only up to
the max. DHW temperature of the heat pump.
Outside temperature from –5 °C to +35 °C
0
DHW temperature in °C
Fig. 4
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
(cont.)
A
6
10
Note
The DHW temperature that the heat pump can achieve
depends on the air intake temperature.
The maximum is 62 °C.
20
30
Outside temperature below –5 °C or above +35 °C
0
10
DHW temperature in °C
Fig. 5
Heat pump
A
Immersion heater
B
DHW temperature achievable with the heat pump
C
DHW heating
11