  • Page 1 VIESMANN Operating instructions for the system user DHW heat pump Type T0E-ze: With immersion heater EHE ■ ■ Type T0S-ze: With connection for external heat generator VITOCAL 060-A Please keep safe. 6136011 GB 6/2019...
  • Page 2 Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Danger Note This symbol warns against the risk of injury. Details identified by the word "Note" contain additional information. Please note This symbol warns against the risk of material losses and environmental pollution.
  • Page 3: For Your Safety

    Safety instructions For your safety (cont.) Conditions for siting Danger Please note Easily flammable liquids and materials (e.g. Unsuitable ambient conditions can lead to sys- naphtha, solvents, cleaning agents, paints or tem damage and can put safe operation at risk. paper) can cause deflagration and fire.
  • Page 4 Index Index 1. Introductory information Symbols ....................Intended use ..................Product information ................Vitocal 060-A ..................■ Outside temperature limits ..............Permissible air intake temperatures ............Commissioning ..................Your system is preset at the factory ............Energy saving tips .................
  • Page 5: Introductory Information

    Introductory information Symbols Symbol Meaning Reference to other document containing further information Step in a diagram: The numbers correspond to the order in which the steps are carried out. Warning of material losses and environ- mental pollution Live electrical area Pay particular attention.
  • Page 6 Introductory information Product information Vitocal 060-A A DHW cylinder is integrated into the type T0E-ze When DHW is being heated, the installation room is DHW heat pump. cooled and dehumidified. The heat pump uses the thermal energy in the indoor or outdoor air for DHW heating.
  • Page 7: Energy Saving Tips

    Introductory information Permissible air intake temperatures The DHW heat pump shuts down outside the permissi- Permissible air intake temperatures: ble air intake temperatures. In some operating pro- ■ For DHW heating in recirculation air mode and recir- grams, DHW can also be heated outside the permissi- culation air mode with air discharge to the outside ble air intake temperatures, through the use of an (temperature in the installation room):...
  • Page 8: Default Display

    Control unit operation Programming unit Default display Fig. 2 OK Confirms your selection or saves the setting made. Selects the operating program. ■ ■ Calls up time programs. ■ Displays information. ■ Takes you one step back in the menu. ■...
  • Page 9: Setting The Dhw Temperature

    DHW heating Setting the DHW temperature Factory setting: 53 °C "ECO" 2. OK to confirm Press the following buttons: to cancel the adjustment. 1. +/− for the required value. Selecting an operating program to select the required operating program. I6 = Off I2 = 0 I6 = On I2 = 1...
  • Page 10 DHW heating Selecting an operating program (cont.) "ECO" operating program DHW is heated by the DHW heat pump only. The Outside temperature below –5 °C or above 35 °C max. achievable DHW temperature depends on the outside temperature: See chapter "Outside tempera- ture limits", page 6.
  • Page 11 DHW heating Selecting an operating program (cont.) "AUTO" operating program DHW is heated by the DHW heat pump as a priority. Outside temperature below –5 °C or above 35 °C ■ ■ Depending on the outside temperature and the set DHW temperature, the immersion heater is automati- cally started too.
  • Page 12 DHW heating Selecting an operating program (cont.) "PROG"/"Night" operating program DHW is heated by the DHW heat pump as a priority Night only: during the time phases selected in the time program. ■ DHW is heated between 23:00 h and 05:00 h. The Depending on the outside temperature and the set start is delayed in such a manner that the set DHW DHW temperature, the immersion heater is automati-...
  • Page 13: Setting The Time Program For Dhw Heating

    DHW heating Selecting an operating program (cont.) Outside temperature from –5 °C to 35 °C Outside temperature below –5 °C or above 35 °C DHW temperature in °C DHW temperature in °C Fig. 16 Fig. 17 Heat pump Heat pump Immersion heater Immersion heater Setting the time program for DHW heating...
  • Page 14 DHW heating Increased DHW hygiene This function allows you to improve the microbiological This function runs regardless of the selected operating quality of the water in the DHW cylinder. This is by program. heating the DHW in your DHW cylinder to 60 °C at reg- As long as this function is active, a rotating is shown ular intervals.
  • Page 15 Power from a photovoltaic system Utilisation of power generated on site You can use the power generated by your photovoltaic For this, consult your contractor. system for DHW heating.
  • Page 16: Restoring Factory Settings (Reset)

    Further settings Time and day To use the PROG operating program, it is essential 4. OK to confirm to set the time and day. Display Meaning Press the following buttons: "MON" Monday "TUE" Tuesday until "TIME" is displayed. "WED" Wednesday 2.
  • Page 17: Calling Up Information

    Checks Calling up information The following information can be called up: Display information ■ Annual consumption (estimated electricity consump- tion) Press the following buttons: Proportion of DHW heating provided by the immer- ■ sion heater and the heat pump in the last 30 days until "INFO"...
  • Page 18 Switching on and off Stopping the DHW heat pump Shutting down the system Disconnect the power plug. Please note If outside temperatures of below -5 °C are expected, take appropriate measures to protect the DHW heat pump from frost. If necessary, contact your contractor. Starting the DHW heat pump After a shutdown or a power failure lasting longer than 24 hours 1.
  • Page 19 What to do if... DHW heat pump does not start Cause Remedy The power plug is not plugged in. Insert the power plug into the socket. ■ ■ An ON/OFF switch installed on site has not been Turn on the mains isolator. ■...
  • Page 20: Inspection And Maintenance

    If there is damage to the connecting cables or lines of the appliance or externally installed accessories, these must be replaced with special cables or lines. Only use Viessmann cables / lines as replacement. For this, notify your qualified contractor. DHW cylinder...
  • Page 21: Information On Disposal

    (Altstoff Recycling Austria AG, licence num- ber 5766). Final decommissioning and disposal of the heating system Viessmann products can be recycled. Components and fluids from your heating systems are not part of ordinary domestic waste. Please speak to your contractor about the correct dis- posal of your old system.
  • Page 22 Keyword index Keyword index Calling up Maintenance...............20 – Information.............. 17 – Cleaning..............20 – Message..............17 – DHW cylinder............20 Childproofing.............. 16 Maintenance contract..........20 Cleaning..............20 Minimum stop time function........21 Comfort (tips)............... 7 Commissioning.............7 Controls................8 Operating program, selecting........9 Outside temperature limits........... 6 Day................16 Default setting..............