<Key operation in this mode>
Whenever the
key is pressed, the display changes.
S
Turn the power breaker OFF after the setting.
USDA SENSOR ON/OFF,
CARGO TEMPERATURE
SENSOR ON/OFF SETTING
S
DEHUMIDIFUCATION
CONTROL ON/OFF
SETTING
S
S
DEFROSTING INTERVAL
AUTOMATIC CHANGING
FUNCTION ON/OFF SETTING
S
DEHUMIDIFICATION
CONTROLCLEARING
FUNCTION ON/OFFSETTING
To set the USDA ON/OFF and CARGO TEMPERATURE SENSOR ON/OFF:
Select "OFF (not in use)", "3 (3 USDA probes are in use)", or "4 (3
USDA probes and 1 cargo temperature sensor are in use)" on the LED
while the LCD displays "USdA".
Whenever the
or
or "4" is changed.
Press the
key to determine the setting.
Note: When two USDA probes are connected, the setting will be
determined automatically to "3" (3 USDA probes are in use).
To set the DEHUMIDIFICATION CONTROL:
Select "ON" (conducting dehumidifying with humidity sensor) or "OFF"
(conducting no dehumidifying) on the LED while the LCD indicates
"dHU".
Whenever the
or
"OFF" is changed.
Press the
key to determine the setting.
Note : This setting can be changed by
ON/OFF setting of defrosting interval automatic changing function
In order to make ON/OFF setting of the defrosting interval automatic
changing function, when the "AUT-INT" is displayed on the LCD
screen, select ON (Use the defrosting interval automatic changing
function) or OFF (Not use the defrosting interval automatic changing
function) displayed on the LED screen.
Every time the "ON" or "OFF" key is pressed, the display will change.
To determine the setting, press the Enter key.
For the contents of the defrosting interval automatic changing function,
refer to information on page 10.
ON/OFF setting of dehumidification control clearing function
In order to make ON/OFF setting of the dehumidification control
clearing function, when the "dHU-CAN" is displayed on the LCD
screen, select ON (Use the dehumidification control clearing function)
or OFF (Not use the dehumidification control clearing function)
displayed on the LED screen.
Every time the "ON" or "OFF" key is pressed, the display will change.
To determine the setting, press the Enter key.
For the contents of the dehumidification control clearing function, refer
to information on page 19.
22
key is pressed, the indication of "OFF" or "3"
key is pressed, the indication of "ON" or
key. (Refer to 3-12)