Table 4-2 LANVIEW LEDs
LED
Color
MGMT
None
Green
Amber
CPU
None
Amber
Green
Red
Green
and
Amber
Amber
and off
State
Off. This module is NOT the
Management Module.
Solid. This module is the
designated Management
Module.
Flashing. This is a
temporary indication that the
module is saving data.
Power off.
Blinking. Module in process
of booting.
Solid. Testing.
Blinking. Image starts
running.
Solid. Functional.
Solid. Processor in reset.
Blinking. Indicates that the
module is in the process of
shutting down.
Alternating (67% on, 33%
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
DFE-Platinum Series Hardware Installation Guide 4-3
Recommended Action
None.
None.
None.
Ensure chassis has adequate power.
None.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
None.
None.
None.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to a start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
While in this state, you have 60 seconds
to safely remove the DFE module from
the chassis.