Installing An Sfp/Xfp (Shown With Lc Connector And Without Dust Cover) - Enterasys G3G124-24 Hardware Installation Manual

G series
Hide thumbs Also See for G3G124-24:
Table of Contents

Advertisement

Connecting to the Network
To install a SFP/XFP, refer to Figure
1.
With an antistatic wrist strap attached to your wrist, remove the transceiver from its 
packaging. If there is a protective dust cover in the transceiver connector, do not remove it at 
this time.
2.
Hold the transceiver so that the connector will seat properly.
3.
Carefully align the transceiver with the port slot as shown in Figure
4.
Push the transceiver into the port slot until it "clicks" and locks into place.
Figure 2-10
1
Release tab
2
Wire handle
3
Transceiver top side
2-18 Installation
Caution: Carefully follow the instructions in this manual to avoid damaging the SFP/XFP and
G-Series.
The SFP/XFP and G-Series are sensitive to static discharges. Use an antistatic wrist strap and
observe all static precautions during this procedure. Failure to do so could result in damage to the
SFP/XFP and G-Series. Always leave the SFP/XFP in the antistatic bag or an equivalent antistatic
container when not installed.
Precaución: Siga las instrucciones del manual para no dañar el SFP/XFP ni del aparato, puesto
que son muy sensible a las descargas de electricidad estática. Utilice la pulsera antiestática y tome
todas las precauciones necesarias durante este procedimiento. Si no lo hace, podría dañar el SFP/
XFP o del aparato. Mientras no esté instalado, mantenga el SFP/XFP en su bolsa antiestática o en
cualquier otro recipiente antiestático.

Installing an SFP/XFP (shown with LC connector and without dust cover)

2‐10 and proceed as follows. 
4
5
6
2‐10.
Edge connector (insertion side)
Port slot
Transceiver side view