Do not start the vehicle w hile the battery charging cable is connected
and the generator is running. The vehicle or the generator may be
damaged.
An overloaded DC circuit, excessive current draw by the battery, or a
w iring problem w ill trip the DC circuit protector (PUSH button extends
out). If this happens, w ait a few m inutes before pushing in the circuit
protector to resum e operation. If the DC circuit protector continues to
go OFF, discontinue charging and see your authorized Honda
generator dealer.
Disconnecting the battery charging cable:
1.
Stop the engine.
2.
Disconnect the black lead of the battery charging cable from the
−
negative ( ) battery term inal.
3.
Disconnect the red lead of the battery charging cable from the
+
positive ( ) battery term inal.
4.
Disconnect the battery charging cable from the DC receptacle of the
generator.
5.
Connect the vehicle battery ground cable to the negative ( ) battery
term inal.
BATTERY CHARGING CABLE
(optional equipment)
BLACK LEAD
−
RED LEAD
25