Viessmann Vitopend 100-W Installation And Service Instructions For Contractors page 45

Gas system and combi boilers for open flue operation natural gas and lpg version
Table of Contents

Advertisement

Repairs
(cont.)
4. Flue gas monitoring sensor:
■ Disconnect the leads from the sen-
sor.
■ Check the sensor resistance and
compare it with the curve.
■ Replace the sensor in the case of
severe deviation.
Note
Function check of the flue gas mon-
itoring device, see page 33.
Checking the fuse
Note
Switch off the power.
5. Cylinder temperature sensor (gas
system boiler):
■ Pull plug % from the cable har-
ness outside the control unit.
■ Check the sensor resistance and
compare it with the curve.
■ Replace the sensor in the case of
severe deviation.
F1
Troubleshooting
45