Flow Limiter; Checking All Gas Equipment For Tightness At Operating; Pressure - Viessmann Vitopend 100-W Installation And Service Instructions For Contractors

Gas system and combi boilers for open flue operation natural gas and lpg version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Further details regarding the individual steps

Flow limiter

If required, flush flow limiter A with
clean water.
Identification of flow limiter A
Rated heating output
10.5 to 24 kW
13.5 to 30 kW
Checking all gas equipment for tightness at operating pressure
Danger
Escaping gas leads to a risk of
explosion.
Check all gas equipment for tight-
ness.
32
(cont.)
Flow rate
10 l/min
12 l/min
Note
Only use suitable and approved leak
detection agents (EN 14291) and devi-
ces for the tightness test. Leak detection
agents with unsuitable constituents (e.g.
nitrites, sulphides) can cause material
damage. Remove residues of the leak
detection agent after testing.
Colour
Black