Energy saving function "Economy mode"
For the preferred heating circuit: display in the
standard menu
21°C
14°C
Flow temperature
Fig. 20
Ending "Economy mode"
■
"Economy mode" ends automatically if the time
program changes to the "Reduced" or "Standby"
operating status.
or
■
Set "Economy mode" to "OFF".
Energy saving function "Holiday program"
Setting the "Holiday program" for central heating/central cooling, ventilation
Note
■
The holiday program applies to all heating/cooling
circuits. Your contractor can change this default set-
ting.
If a ventilation unit is connected to the heat pump
■
control unit, the holiday program also applies to the
mechanical ventilation.
The holiday program starts at 00:00 h on the day fol-
lowing your departure and ends at 00:00 h on the day
of your return. This means that on the days of depar-
ture and return the set time program is active: see
page 27.
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. "Holiday program"
4. Set the required departure and return dates.
(cont.)
Note
■
The display of the set room temperature in the stand-
ard menu does not change.
In "Economy mode", cooling via a heating/cooling
■
HC1
circuit is switched OFF.
■
"Economy mode" cannot be set for a separate
cooling circuit.
40°C
Holiday program
Leaving date:
Date
Return date:
Date
Fig. 21
The holiday program has the following effects:
Central heating:
■
For heating/cooling circuits in the operating pro-
–
gram "Heating and DHW" or "Heating/cooling
and DHW":
The rooms are heated to the set reduced room
temperature: see page 26.
For heating/cooling circuits in the operating pro-
–
gram "Only DHW":
No central heating; frost protection for the heat
pump and heating water buffer cylinder (if installed)
is active.