Jøtul GF 400 DV IPI Sebago Installation And Operation Instructions Manual page 16

Direct vent gas stove
Table of Contents

Advertisement

139548-N GF 400 DV IPI 7/21
Fuel Conversion Procedure
1. Turn off gas supply to stove.
2. Remove the stove Top Plate.
3. Disengage the two Glass Frame Latches and lift the
glass panel frame up and out of the stove.
4. If installed, remove the Embers and Log Set using care
not to damage the fragile log parts.
5. Lift out the Burner Skirt.
6. Reach under the stove and loosen the Air Shutter wing-
nut. Push the shutter stem back to ease burner removal.
See fig. 20.
7. Lift out the Burner Plate with removal of four screws
from the firebox floor. See fig. 21.
8. Change the Burner Injector. See fig. 22. Using a 1/2" open
end wrench or deep-well socket remove the burner
orifice from its elbow housing and replace with the ap-
propriate orifice supplied in the kit.
9. LP CONVERSION ONLY:
A) Install the stop screw into the air shutter plate. This
prevents full air restriction to the burner injector.
See fig. 22.
10. Convert the Pilot Injector:
• Use the 7/16" wrench to remove the pilot head. Grasp
the pilot bracket with pliers or vice-grips to prevent it
from bending out of alignment. See fig.23.
Remove the original pilot injector from the base and
install the new injector oriented as shown.
• Replace the pilot head and tighten the base nut
ensuring that the hood is oriented to direct flame to the
flame sensor and burner carry-over ports.
11. Replace the Burner Plate. Engage the burner tube with
the Air Shutter assembly. Be sure the burner is level and
secure the support brackets to the floor with the screws
previously removed.
12. Replace the Valve Regulator. Using a Torx T-20 screw-
driver, remove the two screws from the front of the
regulator. Remove the regulator components and
replace with the one from the conversion kit. See fig. 24.
13. Install the identification labels to the stove so that they
can be seen by any person who may be servicing the
stove.
Label A: apply to back of stove
Label B: apply to the rating plate attached to the back of
the stove.
Small Conversion Label: apply to valve.
14. Reassemble the stove, apply gas to the system and
check for leaks using a soapy water solution or gas
detector. See Leak Test caution on next page.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
16
Figure 21. Remove four sheet metal screws to lift burner
out of the firebox.
Figure 22. Burner injector
and LP stop screw.
Figure 23.
Change the pilot injector.
Flame
Sensor
DO NOT
BEND PILOT
BRACKET.
Figure 24. Manual Regulator replacement.
Stop Screw
Air Shutte
Injector
Pilot Injector

Hide quick links: