Wall Penetrations - Rinnai RHFE-951ETR Installation Manual

Power flued flamefire space heater co-axial flue system
Hide thumbs Also See for RHFE-951ETR:
Table of Contents

Advertisement

It is critical that any wall penetrations are located correctly.
The enclosure dimensions specified are critical to the successful installation of this appliance
and MUST BE strictly adhered to.
CAUTION
Ensure there are no wall studs, noggins, wiring or other obstruction within the wall cavity where
the flue is proposed to penetrate.
Ensure the location of the flue terminal can comply with the requirements of AS/NZS 5601. Figure
6.2 from AS/NZS 5601 and additional information is shown on page 4.
Especially relevant is the requirement to have a minimum of 300mm clearance between the flue
terminal and the finished ground level. It is not permissible to excavate a hole to obtain the
required 300mm clearance, unless there is sufficient drainage provision.
Ensure the penetration points are marked accurately as this is critical for successful appliance
installation.
The penetration for the flue pipe only needs to be made for 'Direct' and 'Direct Extended' flue
installations, where the flue terminal is located directly to the rear of the appliance.
If no flue pipe penetration is required the markings are still useful for indicating the correct
position of flue exhaust connection of 'Sideways', 'External Wall', 'Internal Wall' and 'Under Floor'
flue applications.
When creating penetrations for flue system installations other than 'Direct' and 'Direct
Extended' the minimum diameter required for the wall penetration of PVC external pipes is 80mm.
IMPORTANT
On all 'Sideways' and 'Under Floor' flue applications, allow for a continuous 2° fall from the
heater connection point to the wall terminal.
Consideration must be given to the position of any studs, noggins or other components of the
wall structure.
RHFE-750ETR / RHFE-752ETR
Mark the location of the gas supply (consumer piping) and flue pipe
penetrations from the centreline
following dimensions:
Centreline of enclosure
1
400 mm RIGHT of centreline
2
55 mm from base of enclosure
378 mm LEFT of centreline
4
580 mm from base of enclosure plus or minus 25mm
5
RHFE-950ETR / RHFE-951ETR
Mark the location of the gas supply (consumer piping) and flue pipe
penetrations from the centreline
following dimensions:
Centreline of appliance
1
420 mm LEFT of centreline
2
65 mm from base of enclosure
430 mm RIGHT of centreline
4
500 mm from base of enclosure plus or minus 25mm
5
RHFE-1250ETR
Mark the location of the gas supply (consumer piping) and flue pipe
penetrations from the centreline
following dimensions:
Centreline of appliance
1
570 mm LEFT of centreline
2
65 mm from base of enclosure
580 mm RIGHT of centreline
4
500 mm from base of enclosure plus or minus 25mm
5
Rinnai

WALL PENETRATIONS

of the heater enclosure using the
1
of the heater enclosure using the
1
of the heater enclosure using the
1
8
Flue pipe penetration
1
Gas supply penetration
Ø 100
4
5
2
3
Flue pipe penetration
1
Gas supply penetration
Ø 100
4
2
3
Flue pipe penetration
1
Gas supply penetration
Ø 100
4
2
3
POWER FLUED FLAMEFIRE FIM
5