Flue Transition Connections; Location; Lubricating Inner Pipe Components - Rinnai RHFE-951ETR Installation Manual

Power flued flamefire space heater co-axial flue system
Hide thumbs Also See for RHFE-951ETR:
Table of Contents

Advertisement

REGULATIONS, CLEARANCES & GENERAL INFORMATION

FLUE TRANSITION CONNECTIONS

2
1
1
Flue exhaust connection to heater.
right hand ~ small connection not used).
the large and small combustion air inlet and MUST cover the air inlet not in use.
Exhaust outlet.

LOCATION

This appliance MUST NOT be installed where curtains or other combustible materials could come into contact with
it. In some cases curtains may need restraining.
Heat emanating from the front
of this appliance may over time
affect the appearance of some
materials used for flooring such
as carpet, vinyl, cork or timber.
This effect may be amplified if
the air in the room contains
cooking vapours or cigarette
smoke. To avoid this possibility,
it is recommended that a mat be
placed in front of the appliance,
extending at least 750mm in
front of it.
The flue terminal MUST BE positioned away from flammable materials.
In areas subject to heavy snowfall, keep snow clear of flue terminal at all times.
• DO NOT flue into natural
draught flues or fireplaces.
• DO NOT flue into other
rooms, roof spaces or into
under floor spaces.
• DO NOT Install the heater in
an unusually dusty area.
For other important information regarding the location of the heater refer to the instructions
supplied with the appliance.
IMPORTANT

LUBRICATING INNER PIPE COMPONENTS

The inner flue pipe joints are sealed with an "O" ring seal.
To ease assembly, a small container of silicone grease is provided with the Direct Flue Kit (ASPDFK) and the Flue
Adaption Kit (ASPKIT03). Use this silicone grease to lubricate the "O" ring on the inner pipes prior to assembly.
Use ONLY the supplied silicone based "O Ring" seal lubricant.
DO NOT use petroleum based lubricants such as petroleum jelly. The use of petroleum jelly,
CAUTION
®
vaseline
or similar petroleum based lubricants will cause deterioration of the "O" ring seals.
Rinnai
3
5
4
2
Combustion air inlet connection to heater (Left hand ~ Large connection,
Rubber combustion air inlet cap (when supplied) is designed to fit both
3
1 0 0 m
m
1 0 0 m
The above diagram shows the clearances required
around this heater.
DO N OT
DO N OT
5
4
2
DO NOT
m
DO N OT
5
3
1
Combustion air inlet.
4
DO N OT
POWER FLUED FLAMEFIRE FIM
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rhfe-752etrRhfe-950etrRhfe-750etrRhfe-1250etr

Table of Contents