York 21RT-47RT Installation, Operation And Maintenance Manual page 37

Water-cooled chiller
Table of Contents

Advertisement

3)
Communication flashing display: display of flashing icon
4)
Others will not be shown
4.4.2 Screen saver status
Backlight off
4.4.3 Daily display status
Serial
Number Display Area
1
Time display
area
2
Timing
display area
3
Temperature
display area
4
Code number
display area
5
Operation
mode display
area
6
Status display
area
7
Touch screen
key display
area
Description of displaying temperature
Cooke Industries - Phone: +64 9 579 2185
Operation instructions of wire controller
Display content (daily display)
Power
Power On
Off
The current date and time of the system can be modified by wire controller, and
the default value is 2000-1-1 0:00.
If there is a timing setting: the clock flag will be displayed, otherwise it will not
be displayed;
If there is timing ON or OFF settings, the timing mode will be displayed.
When there is no occurrence of fault, the current actual controlled water
temperature shall be displayed. When there occurs any fault,
No
Display
will flash; Otherwise, the icon
code for that fault will be displayed in the form of flashing digit. When
there are multiple faults, the code of the last fault will be displayed.
When there is any fault, the second digit will display the module No. In
fault's inquiry interface, the first digit will display the module No. of
the fault, and the second digit will display the serial No. of the fault.
No
For the daily display interface, when there is no fault, it will show the
Display
loading rate, for example, if it displays 50, it indicates that the loading
rate is 50%; if it displays FC (Full Capacity), it indicates that the
loading rate is 100%.
Display the current user setting modes of the unit connected by wire
No
controller.
Display
From the left to the right, the order shall be as follows:
Sign of low sound
: this will display during the mute mode or when there is a
low sound mode in the night; otherwise, this will not be displayed.
Sign of communication
the display wire controller and the unit.
Sign of wire-controller lock's status
current wire-controller lock's status.
Sign of keypad lock's status
keypad lock's status.
Sign of compressor's status
flash; when the compressor is started, this will display, and this will not display at
other time.
Sign of water pump's status
display; otherwise, this will not display.
Display all keys
34
Email: sales@cookeindustries.co.nz
will not be displayed; The fault
: this indicates the current communication status of
: this will be displayed according to
: this will b e displayed according to current
: When the compressor is warm- up, this will
: When the water pump is in operation, this will
Web: www.cookeindustries.co.nz