Main Screen

After the AQ Wireless powers up and initializes, one main screens will appear. The
screen are meant to provide meaningful feedback to an operator during an assembly
process.
Tools will transmit a packet at the end of a fastening process.
Main Screen (Definitions):
GROUP: displays the group (parameter) that is currently being used, the type of tool,
and the name of the tool.
STATUS: shows whether or not the previous fastening was successful and met all
requirements. OK is displayed if fastening is successful. NOK and a reason are
displayed if the fastening fails.
COUNT: the number indicates how many fastenings in the batch have been completed.
BATCH: displays the quantity in a batch.
TOTAL: displays the number of batches that have been successfully completed.
There are four soft functions associated with the soft-key at the bottom of the screen.
If the unit is unlocked, pressing one of the buttons will take the user directly to that
function. The soft functions listed at the bottom of the main screen are Autocal, View
Run, Batch Reset, and More.
Autocal
The AUTOCAL function provides a default values are written to the current group
(parameter).
View Run
This feature isn't compatible.
Batch Reset
The BATCH RST button leads to a screen where the batch, the total, or both can be
reset.
Tools utilize a main screen that predominately features
the count and batch values. The group (parameter), tool
name, tool type, status, and total are also visible.