Edit Group - Panasonic EYFRZ01 Operating Instructions Manual

Assembly qualifier
Table of Contents

Advertisement

Edit Group:

Battery tools have multiple timers, a batch value and a tool name which can be edited.
In order to edit a value, press the number associated with that value. In most cases
the unit will go to a screen that allows the user to type in a new value for the item
being edited. In some cases where only a few options are available, pressing the
number associated with the item to edit will toggle that item to a new value.
When the group is entirely edited, pressing the ENTER key will store that group to
non-volatile memory so that the values can be remembered the next time the unit is
powered down and then back up again. The ESCAPE key can also be pressed to
leave the edit screen without saving any new values.
EDIT SCREEN DEFINITIONS :
TBC - Time Between Cycles. After a good cycle, this timer will start. The unit will not
allow another good fastening until after this timer expires.
TBB - Time Between Batches. After a batch is complete, this timer will start. The unit
will not allow another good fastening until after this timer expires.
Batch - Number of fasteners to be tightened in this assembly.
Name - Name associated with this tool.
There are eight different groups or parameter sets
available in the AQ Wireless. Each group can represent
one tool and it's associated settings.
So, this unit can be used with multiple tools. Each new
tool would have to be learned into a given group
(parameter).
The unit can also be used with a single tool but different
setups.
In order to edit a group, press the EDIT GROUP soft-
key on the menu screen.
At this point, the user will be asked to select the group
they wish to edit.
Groups A through H are represented by soft-keys 0
through . Pressing a number key will send the unit to
an edit screen for that group.
- 11 -

Advertisement

Table of Contents
loading

Table of Contents