Coolant Filter Replacement (Without Coolant Flush) - Lincoln Electric FineLine 12864 Operator's Manual

300hd plasma system
Table of Contents

Advertisement

FineLine 300HD Plasma System

6.2 Coolant Filter Replacement (without coolant flush)

Important: When handling coolant, wear nitrile gloves and safety glasses.
Remove primary (wall) power from the System.
Use a Torx T27 screwdriver to loosen the four screws on the right side of the
Power Supply that secure the coolant filter access panel. Remove the coolant
filter access panel.
Unscrew the filter housing (turn to the left) and then carefully remove it from the
Power Supply. Minimize spilled coolant. Wipe up any spilled coolant.
Remove the dirty coolant filter cartridge from the housing and replace with new
coolant filter cartridge part number KP4730-1.
Re-install the filter housing into the Power Supply and tighten by hand (turn to
the right). Wipe up any spilled coolant.
Replace the coolant filter access panel and then tighten the four screws.
End of procedure.
Coolant Filter
Housing Removed
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Coolant Filter
Access Panel
Removed
Figure 13: Coolant Filter Replacement
Page 78 of 118
BK8053-000107 Rev A.01