Emergency Stop (Estop) Circuit - Lincoln Electric FineLine 12864 Operator's Manual

300hd plasma system
Table of Contents

Advertisement

BK8053-000107 Rev A.01

3.14 Emergency Stop (EStop) Circuit

The FineLine 300HD System incorporates an EStop circuit meeting Performance
Level (d) Category 3 requirements as per ISO 13849-1 and IEC 62061 standards.
The EStop circuit employs a Safety Relay which controls both the Power Supply and
AGC outputs, disabling both when the EStop is engaged.
The OEM or end user must supply the EStop enable/disable switches and wiring.
The Safety Relay employs dual monitored EStop input circuits. Both are required
and must be isolated from each other for proper operation. Switch contacts must be
rated for 35 VDC, 100mA.
Refer to Figure 12 for the physical location of all connections. Replace the access
panel on the Power Supply when installation is complete
Power Supply to EStop Connections
1) On the rear of the Power Supply, remove the two jumper wires from
2) Connect the EStop wiring to the terminal block as shown. Route wiring
Access Panel
Removed
Route
through
opening
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
the terminal block labelled with the symbol shown.
through the opening on the rear of the power supply.
Figure 12: EStop Circuit
Page 43 of 118
FineLine 300HD Plasma System
Pos 12, EStop 2B
Pos 11, EStop 2A
Pos 2, EStop 1B
Pos 1, EStop 1A
EStop
Switch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents