Large Multi-Purpose Indicator Setting Changing Function - Panasonic SFC-HC Instruction Manual

Handy controller exclusive for sf4c series
Table of Contents

Advertisement

Functional Descriptions
3-1-8

Large Multi-purpose Indicator Setting Changing Function

One mode can be selected from the following 8 modes
Factory setting is mode 0.
Large multi-purpose
Mode
indicator input 1
PNP output:
High
0
Lights up in red
1
Blinks in red
2
Lights up in red
3
Blinks in red
4
Lights up in red
(Note 1)
5
Blinks in green
(Note 1)
6
(Note 1)
7
Lights up in red
(Note 1)
Notes: 1) Blinking takes precedence in case of same color brinks or light up in the large multi-purpose indicator.
2) The large multi-purpose indicator (red) and the large multi-purpose indicator (green) can be lit up and blinked in same
time.
Furthermore, large multi-purpose indicator (red) can be blinked in lockout status.
Lockout blinking display function
Valid
Invalid
15
When using the device in PNP output (or NPN output), use PNP output (or NPN output)
safety sensor. The control output (OSSD 1 / 2) becomes OFF by using wrong output type
of sensor.
Series connection is also available when connecting other SF4C series to the safety in-
put 1 / 2. However, this device does not incorporate the interference prevention function.
7KXV WDNH VXI¿FLHQW FDUH ZKHQ LQVWDOOLQJ WKH GHYLFHV
Use a safety sensor which incorporates a crossover short-circuit function in the control
output and connect both the safety input 1 wire (gray) and the safety input 2 wire (gray /
black). Take care that if only one wire is connected, the device may not operate normally.
Use a safety contacting point which incorporates two NC (Normally Closed) contacting
points and connect both the safety input 1 wire (gray) and the safety input 2 wire (gray /
black). Take care that if only one wire is connected, the device may not operate normally.
In case setting the safety contacting point input mode or the safety sensor input mode,
connect to +V or 0V as a following table when safety input function is not used.
Safety input
setting chang-
Safety input 1 wire
ing function
Safety con-
tacting point
Connect to +V
input mode
Safety sensor
Connect to +V
input mode
Operation of large multi-purpose indicator
Large multi-purpose
indicator input 2
NPN output:
PNP output:
Low
Low
Lights up in green
Blinks in green
Blinks in green
Lights up in green
Blinks in red
Lights up in green
-
Blinks in red
Lockout ON
Blinks in red
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SFCHC No.0037-80V
For PNP output
Safety input 2 wire
(gray)
(gray / black)
Connect to 0V
Connect to +V
Control output 1 / 2
(OSSD 1 / 2)
NPN output
ON
High
-
-
-
-
-
-
Lights up
-
in green
-
-
For NPN output
Safety input 1 wire
Safety input 2 wire
(gray)
(gray / black)
Connect to +V
Connect to 0V
Connect to 0V
Connect to 0V
Muting
function
OFF
Valid
-
-
-
-
-
-
-
-
-
-
-
-
Lights up
Blinks in
in red
green
Lights up
-
in green
Override
function
Valid
-
-
-
-
-
-
-
Blinks in
green

Advertisement