<In case using this device with cable type of SF4C series>
Wire a discrete connection cable with connector on one end SFC-WNC1 (optional) to this device.
And wire a clip of the discrete connection cable with connector on one end to a lead wire of cable
type of SF4C series.
It is also possible to use in condition that an intermediate connector type of SF4C series is wired
to a cable with connector on one end 6)%&& 08 (optional).
<For PNP output>
Emitter
Connection cable with a
connector on one end
This device
Connection cable with a connector on one end: 1 pc./set
Model No.
Cable length
SFC-WNC1
‡ The setting procedure remains the same.
‡ The control output (OSSD 1 / 2) of SF4C series is set to "OFF" while this device has been con-
nected. Once the setting is completed, turn OFF the power, remove this device and then turn ON
the power again.
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SFCHC No.0037-80V
Receiver
+
24V±10%
-
3m
Cable which incorporates clips on end of the discrete wire.
When the lead wire contacts with other lead wires, maximally 26.4V DC of voltage is ap-
SOLHG DQG $ RI FXUUHQW ÀRZV
In case the connecting cable with connector on one end connected the cable type of
SF4C series or the intermediate connector type to this device, lead wire may be discon-
nected. Be sure the lead wire is not disconnected.
Connecting / Setting Procedures
<For NPN output>
Emitter
Connection cable with a
connector on one end
This device
Description
Receiver
+
24V±10%
-
8