FASTENING THE COOKTOP
Each cooktop is supplied with a set of tabs and screws
to fasten it on units with a working surface from 3 to 4
cm deep.
The kit includes 4 tabs A and 4 self-threading screws B
(fig. 4.4)
• Cut the unit
• Turn the hob upside down and rest the glass side on
a cloth.
• Spread the seal C around the edge of the hob(fig. 4.5)
• Put tabs A into the mountings; only tighten screws B
a few turns.
• Make sure that the tabs are mounted correctly as
shown in the figure 4.4
• Put the cooktop into the hole cut into the unit and
position it correctly.
• Put tabs A into place, tooth D of the tabs should go
into the hole.
• Tighten screws B until the cooktop is completely
secured.
• Using a sharp tool cut off the part of gasket C which
protrudes from the cooktop. Take care not to damage
the workbench.
IMPORTANT: Installation must be carried out according to the manufacturer's instructions. Incorrect installation
may cause harm and damage to people, animals or property, for which the manufacturer accepts no responsibility.
Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains.
Connection to a good earth wiring system is absolutely essential.
The manufacturer accepts no responsibility for any inconvenience caused by failure to comply with this rule.
ELECTRICAL REQUIREMENTS
• Connection to the electric power supply must be carried out by a qualified technician and following the
appropriate safety regulations.
• The appliance must be connected to the mains checking that the voltage corresponds to the value given in the
rating plate and that the electrical cable sections can withstand the load specified on the plate.
• If the hob is supplied without plug, fit a standard device which is suitable for the power absorbed by the
appliance and in conformity with the local rules in force.
• A suitable isolating switch providing full disconnection from the mains power supply shall be incorporated in the
permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. The isolating
switch must be of an approved type and provide a 3 mm air gap contact separation in all poles.
• The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 50 ℃
above ambient.
• Once the appliance has been installed, the power switch must always be in a accessible position.
N.B. For connections to the mains power supply, never use adaptors, reductions or multiple power points as
these may overheat and catch fire.
In the event that installation should require modifications to the mains supply wiring system, it is recommended
that a qualified technician be called to carry out substitution.
The technician will also have to verify that the cross-section of the electric cables on the power point match the
ELECTRICAL CONNECTION