Daily inspection and Rinnai built in hob are meticulously designed to meet your requirements. maintenance....To maintain your built in hob in Easy repair......optimum condition, please read this manual carefully before use.
Page 2
Gas pipe diameter mmH O (mm) Gas Pressure Gas Consumption Single: (kW) Both: (kW) Connector Diameter 9.5mm(Specialized Rubber Pipe) ∅ RB-27F Weight Left:4.2 Right:4.2 Thermal Efficiency Above 50% RB-27GF Single consumption Rinnei Taiwan Corporation (kw) RB-37F L:4.2 M:2.9 S:1.4 RB-37GF 1.
3. Product features 1.Specially designed strong burner, prevents build up of residue. 2.Stage heat control, suitable for various cooking methods. 3.Super energy saving design conforms to national energy conservation mark, with heat efficiency reaching above 50%. 4.Suitable for all kinds of Chinese cooking. 5.Extinguish safety device installed.
Page 5
Opening dimension Kitchen counter opening dimension C(min) Model no. RB-27F RB-37F RB-27GF RB-37GF Diagram 4 Adjusting c. Assembling method and notes screw (4 pcs) Stainless steel gas built in hob assembling method 1. Place built in hob into opening (see diagram 4).
Page 6
d. Gas pipe installation 1.Do not use PVC pipes. Use only oil proof, heat proof gas pipes. 2.Do not bend gas pipe during installation. Pipe length should not exceed 2m. built in hob built 3.Do not allow pipe to come into contact with main body or pass under in hob to avoid melting from high heat.
5. Operation method A. Ignition operation Make sure switch knob is turned upwards (as shown in diagram). Press knob down, do not let go, turn anti-clockwise to ignition position (as shown in diagram). When flames appear, let go of knob. 3.
Page 8
6. Attention a. Special notes 1. Use only the gas type specified on name plate. 2. Do not use built in hob for purposes other than cooking, such as clothes drying etc… 3. Do not cover burner support with iron sheet or stone slate during use. This will affect heat dissipation, causing spare parts to burn-out and lead to fire breakouts.
Page 9
d. Gas leak prevention and countermeasures 1. Use only certified rubber piping. Ordinary piping is strictly forbidden (no resilience and not heat proof). 2. Check rubber piping regularly. If signs of ageing, fracture, or slackness are found, please replace immediately. Certified Fractured 3.
7. Daily inspection and maintenance Reminder 1. Prior to inspection and maintenance, confirm gas is turned off and stove has cooled down. 2. During inspection and maintenance, if abnormalities are found, please contact our service center immediately. For inspection items not listed below, especially ser vices that include safety device and gas piping, please contact our ser vice center.
Page 11
Not using built in hob for a long time 1. Please block gas pipe (such as entrance to pipe connector) to prevent blockage caused by foreign matter. 2. Clear away all residues, and cover with plastic bag to prevent dust and foreign matter from entering.