* THE FREQUENCY OF CLEANING SHOULD BE INCREASED IF THE PELLETS ARE OF POOR QUALITY.
We recommend this maintenance be done annually (with a scheduled service contract), which focuses on a visual and functional
check of the inner components. Below is a summary of the checks and/or service that are essential for proper product operation.
• Gear motor
• Smoke extraction fan
• Smoke probe
• Ignition spark plug
• Pellet/water automatically rearming thermostat
• Room/water probe
• Motherboard
• Panel-board protective fuses
• Wiring
16

IN CASE OF ANOMALY

16.1 PROBLEM SOLVING

Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to
avoi irreparable damages!
PROBLEM
CAUSE
The stove is
without power
supply
Burned protection
fuse in the electric
socket
The control display
Faulty control
does not switch on
display
Faulty flat cable
Faulty electronic
board
28
SOLUTION
Check if the plug is connected.
Replace the protection fuses in the electric socket (3.15A-
250V).
Replace the control display.
Replace the flat cable.
Replace the mother board.
INTERVENTION
IDROSTUFE