Brother MFC260C Service Manual page 79

Facsimile equipment
Hide thumbs Also See for MFC260C:
Table of Contents

Advertisement

(5) Air removing mechanism
Another position of the purge cam shifts the slide cams, producing vertical motion of the air vent
rods. Pushing up the air vent rods opens the shut-off valves inside the air vent unit of the
head/carriage unit. Simultaneously adding negative pressure from the tube pump removes air
trapped in the damper assemblies.
Clutch gear
Damper ASSY (Black)
Left chamber
Damper ASSY (Yellow)
Left chamber
Damper ASSY (Cyan)
Left chamber
Damper ASSY (Magenta)
Left chamber
Purge gear
Slide cam
for color ink
Purge cam
3-28
Maintenance unit
Air vent rods
Air vent cap
Right chamber
Right chamber
Right
chamber
(Air vent rods)
(A part of maintenance unit)
Right chamber
Slide cam
for black ink
(3_12)
Shut-off valves
Air vent unit
(Air vent cap)
(BackEnd)
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc685cwMfc680cnMfc465cnMfc265cMfc885cwMfc235c