Brother MFC260C Service Manual page 410

Facsimile equipment
Hide thumbs Also See for MFC260C:
Table of Contents

Advertisement

Selector
No.
1
Dial tone/busy tone detection
|
level during recording of ICM
3
4
|
Not used.
8
NOTE: Selectors 1 through 3 are applicable to models with built-in TAD.
Selectors 1 through 3: Dial tone/busy tone detection level during recording of ICM
If the machine (called station) detects dial tone (400 Hz continuously) or busy tone (400 Hz
intermittently) exceeding the detection level specified by these selectors for the period specified by
selectors 1 through 4 on WSW35, then it interprets the calling station as being disconnected. The
machine stops TAD recording and disconnects the line.
WSW30
(Function setting 8)
Function
App. 4-34
Setting and Specifications
No. 1 2 3
0 0 0
:
-38.0 dBm (A)
0 0 1
:
-39.5 dBm (B)
0 1 0
:
-41.0 dBm (C)
0 1 1
:
-42.5 dBm (D)
1 0 0
:
-44.0 dBm (E)
1 0 1
:
-45.5 dBm (F)
1 1 0
:
-47.0 dBm (G)
1 1 1
:
-48.5 dBm (H)