Updating The Chassis Id - Fujitsu PRIMERGY PG-R1CK6 User Manual

F200 rack conversion kit
Table of Contents

Advertisement

15

Updating the Chassis ID

After installing the server to the rack, update the chassis ID as follows:
1
Check that no media has been left in the floppy disk drive, CD-ROM,
etc.
2
Turn on the display and any attached peripherals.
3
Insert the "Hardware Configuration Tool Boot Floppy" provided with the
server in the floppy disk drive and turn on the server.
The menu will appear.
4
Select "Server Management Tool" from menu and press [Enter].
After appearing the DOS prompt, remove the "Hardware Configuration Tool Boot
Floppy".
5
Insert the "Server Management Tools" disk provided with the server into
the floppy disk drive and type the following commands:
A:\>WRTID.BAT F200R.ini
The following message appears when properly executed.
Normal End
6
Turn off the server.
30
Conversion procedure
Before rebooting the system from the ServerStart CD or "Hard-
ware Configuration Tool Floppy", first check that the ServerView
"OS Boot Monitoring" function has been disabled (default setting
is "Disabled").
If the system is started with the "OS Boot Monitoring" function
enabled, the server is liable to automatically shutdown and/or
reboot and/or perform other unexpected operations.
If the "OS Boot Monitoring" function is needed, it should be reset
to enabled before resuming normal server operation.
See the "Server View User's Guide" on ServerVIew CD-ROM for
more ServerView information.
A "Hardware Configuration Tool Boot Floppy" may be created
using the ServerStart CD.
For details on how to create, refer to "PRIMERGY F200 Supple-
ment".
[Enter]