SECO-LARM E-941DA-600Q Manual

SECO-LARM E-941DA-600Q Manual

Double-door electromagnetic lock
Hide thumbs Also See for E-941DA-600Q:

Advertisement

Quick Links

Double-Door Electromagnetic Lock
E-941DA-600Q
600-lb. (272kg)
E-941DA-1K2Q
1200-lb. (545kg)
With LED, Bond Sensor
E-941DA-600PQ
600-lb. (272kg)
E-941DA-1K2P
1200-lb. (545kg)
MANUAL
NOTE: Products with model numbers ending in "Q" or labeled with a round green "Q" sticker are certified RoHS compliant.

Advertisement

Table of Contents
loading

Summary of Contents for SECO-LARM E-941DA-600Q

  • Page 1 Double-Door Electromagnetic Lock E-941DA-600Q 600-lb. (272kg) E-941DA-1K2Q 1200-lb. (545kg) With LED, Bond Sensor E-941DA-600PQ 600-lb. (272kg) E-941DA-1K2P 1200-lb. (545kg) MANUAL NOTE: Products with model numbers ending in "Q" or labeled with a round green "Q" sticker are certified RoHS compliant.
  • Page 2: Parts List

    ” x 1 ” (185 x 12 x 38 mm) Armature plate 1,200-lb. ” x ” x 2 ” (185 x 16 x 61 mm) Operating temperature 14°~131° F (-10°~55° C) 600-lb 9lbs. (4kg) Weight 1,200-lb. 21lbs. (10kg) SECO-LARM U.S.A., Inc.
  • Page 3: Typical Installation

    Use the diagram below to help decide whether or not an optional bracket will be necessary for installation. See page 7 for a complete list of SECO-LARM accessories. Typical Plate “L”...
  • Page 4: Installation Notes

    Please see the diagram on page 3 to decide if a particular application requires any mounting accessories. See page 7 for a complete list of SECO-LARM accessories. 4. Do not run power wires and signal wires in the same conduit as this may cause interference.
  • Page 5 Keeping them loose will allow for adjustment of the plate left or right so that the mounting plate and the armature plates form a 90-degree angle. See the diagram below. 90° Mounting Plate Short self-tapping screws Armature Plate SECO-LARM U.S.A., Inc.
  • Page 6: Also Available From Seco-Larm

    NOTE: Failure to correctly set the input NOTE: This should be the very last step, as once the voltage may cause damage to the lock. tamper caps are in place they are very difficult to remove. Also Available from SECO-LARM: Access Control Stand-Alone Complete line of...
  • Page 7: Wiring Diagram

    12VDC operation 24VDC operation Maximum Distance from Power Source to Electromagnetic Lock: For a complete chart, please visit www.seco-larm.com 12VDC Minimum Wire Gauge: Wire Length 25ft. 50ft. 75ft. 100ft. 150ft. 200ft. 250ft. 300ft. 400ft. 500ft. 1000ft.
  • Page 8: Troubleshooting

    LIFETIME LIMITED WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation.

This manual is also suitable for:

E-941da-1k2q

Table of Contents