Appendix B: Pinout Assignments
Alarm Examples
Table 24
Ethernet Port
There are 6 RJ-45 and 2 SFP connectors on the front of the 7705 SAR-F that provide
Ethernet access to 8 Ethernet ports.
Use CAT5 (Fast Ethernet) or CAT5E (Gigabit Ethernet) shielded cables to attach customer
equipment to the 7705 SAR-F Ethernet ports.
Figure 29
Page 112
Table 23: External Alarms Port Pinouts—DB15 Female (Continued)
Pin
Signal
14
Alarm output 1, pin 2
15
Alarm output 1, pin 1
lists critical, major, and minor alarm examples.
Alarm Severity
Critical
Major
Minor
shows the pin numbering.
Direction
Output
Output
Table 24: Alarm Examples
Examples
• two or more fans have failed
• a power feed has failed
• a critical external alarm has been detected
• an over-temperature condition has been detected
• a major external alarm has been detected
• one fan has failed
• a minor external alarm has been detected
7705 SAR-F Installation Guide
Description
Contact closes on critical alarm
Contact closes on critical alarm