Theory of Operation Ver. 1.1 Apr. 2010

10. IMAGING UNIT SECTION

10.1 Configuration

Cleaning Blade
Drum Charge Corona
Agitating screw

10.2 Operation

10.2.1

Imaging unit life detection

• The life of the imaging unit is calculated using the period of time through which the drum
is rotated (main motor drive time).
• When the drum rotation time reaches the life value, the life message appear on the con-
trol panel.
Life status
Life
Life stop
TCR sensor board
Approx. number of prints upon detection
55K
69K
10. IMAGING UNIT SECTION
Toner conveyance screw/1
Toner scooping screw
drum Paper Separator
Fingers
Drum
Developing Roller
Toner supply screw
A0XXT2C548AA
A0XXT2C511AA
23