Download Print this page
NCR IBM 7870 Quick Start Manual
NCR IBM 7870 Quick Start Manual

NCR IBM 7870 Quick Start Manual

Advertisement

Quick Links

IBM 7870 Model 2000
Specifications
Standard Features
• Bi-Optical (12/12 line) Scan Zone
• Label Configuration Control
• Speaker Volume
• Voice Processor for messages
• Soft power down mode
• 9 pin RS-232 for POS terminals
• NCR Pacesetter plus electronics decoding logic
• Auto-discriminate symbology
• Sealed load cell for scale
• High can reading- 8" above lower glass
Optional Features
• Multiple glass options
Symbologies
• UPC-A,D,E -Universal product code
• EAN - International Article Numbering
• JAN - Japanese Article Numbering
• Code 39 -- Code 3 of 9
• Code 128
• I2 of 5 - Interleaved 2 of 5
• Add-On codes (2 and 5)
• NOF -- Not on file
Programmable Functions
• Scanner Reset Symbol
• Scanner Test Mode Enable/Disable
• Good Tone Frequency and Length Adjust
• Volume Adjustment
• Add-On Code Enable/Disable
• Code 39,128 And Interleave 2 Of 5 Enable/Disable
• Tag Lockout Time Increase/Decrease
• Same Tag Lockout Re-Trigger
• Inactivity Time Or Immediate To Soft Power Down
• Dual Versus Single Cable Communications
• Toggle NCR/Non-NCR Format
• Interface Selection Or Disable Scale Usage
• Slow Power Up For Scale
• Scale Display Zero After Five Seconds
• Weight Timeout Enable/Disable
Dimensions
• 17" h x 19" w x 24" d
IBM Document: NCR
Page 1 of 3
Specifications (Continued)
Weight
• Installed: 34 lb.
• Shipping: 40 lb.
Power Supply
• External AC adapter @ 43 watts providing +12VDC,
+5VDC, -12VDC with a 5 Amp maximum.
Tools Requirements
• Flat-Blade Screwdriver
• Certified Calibration Weight Set
• Anti-Static Strap
Special Notes:
• DANGER:- Due to the fact that this is a Class IIa laser
product it is strongly advised to "Avoid long-term
viewing of direct laser light" at all times.
• Scale calibration is generally done after the following:
scale installation, load cell or board replacement, scale
will not zero, calibration error occurs, changing weight
formats from pounds to metric.
• Scale calibration gives better results if the scale is
warmed up prior to the calibration by placing and
removing weights on the scale from 5 to 30 pounds and
then removing them.
• The NCR7870 Model 2000 should not be placed back in
service after it has been repaired or for its initial operation
until a certified field engineer has performed a weight
calibration based on the state and national government
specifications. If the calibration can not be performed
then an "Out of order" must be placed on the unit. A seal
may be also be required in order to validate the calibration
procedure based on government standards in your area.
• NCR Pacesetter Plus has three modes: Inquiry mode
allows scanner to track various information about labels
scanned, Real-Time mode allows off-line tally and checkly
of labels for searching and determining the bad labels
within a given stock of items, Mode 3 is just like Inquiry
mode but it appends the tracking information to the
barcode information so the terminal can extract this
information and add it to a database for reports or for
other tracking needs.
Scale Error Codes
Code
Description
1- 3
Calibration Failure
4
Scale error / vibs in calibrate
5
Scale drifting or object in it.
6
EEPROM Failure
7
Board Replaced
8
Weight Constants Failed
9
Interference in calibration
Blank
Object in or on it in calibrate
© Copyright International Business Machines, 1997
NCR
7870 Model 2000
To Fix It
Chg. Scale Brd/Cell
Reset / Recalibrate
Clr. obj. /Reset/ Cal.
Chg. Scale Board
Recalibrate
Chg. Digital Brd.
Recalibrate
Clear object / Reset
06/97 Doc # NCR001
All rights reserved

Advertisement

loading

Summary of Contents for NCR IBM 7870

  • Page 1 • NOF -- Not on file procedure based on government standards in your area. • NCR Pacesetter Plus has three modes: Inquiry mode Programmable Functions allows scanner to track various information about labels •...
  • Page 2 • Place the same weight on 4 different areas on the Top- • Do Procedure (Installing Top-Plate and Sub-Plate) plate, verify the weight is within a .02 offset. IBM Document: NCR 06/97 Doc # NCR001 © Copyright International Business Machines, 1997...
  • Page 3 Remote Pole Video Display 7870-7825 20H7857 Repeats Repeats Speaker 006-1010870 20H7849 1 - Yes 1 - Yes Sleep Mode Scan Something IBM Document: NCR 06/97 Doc # NCR001 © Copyright International Business Machines, 1997 Page 3 of 3 All rights reserved...

This manual is also suitable for:

2000