ANTI-FREEZE FUNCTION

The anti-freeze function is the appliances automatic protection to avoid damages caused by very low
tempe ratures below 5 °C, in the event in which the product is turned off during winter. It is recommended
that the product remains plugged in to the mains power, even if iiis inactive for a long time. The function
is enabled; activation is displayed on the display with "AF". For all models, once the temperature rises to
a safer level such as to avoid damage from ice and frost, the water heating is switched off again.
THERMAL DISINFECTION FUNCTION (ANTI-LEGIONELLA)
The anti-Legionella function is activated by default. It consists of a water heating/60°C temperature main-
tenance cycle for 1 hour which has a thermal disinfection action on the relative bacteria.
The cycle starts when the product is started up and when it is restarted after a power outage. If the
product always functions at temperatures lower than 55°C, the cycle is repeated after 30 days. When the
product is switched off , the anti-Legionella function is deactivated. If the equipment is switched off during
the anti Legionella cycle, the product switches off and the function is deactivated. At the end of the cycle,
the use temperature returns to the temperature previously set by the user.
To activate or deactivate the function, press the "FAST/ " knob for 5 seconds; the display will show
"A0" (deactivated) or "A1" (activated). Turn the knob to change the setting.
To confirm the activation/deactivation, the product will return to the normal operating status after 5
seconds.
RESET/DIAGNOSTICS
When any of the operation problems occur, the appliance goes into "fault status" and the corresponding error
code fl ashes on the display (for example, 1).The error codes are the following:
ERROR TYPE
Not Volatile Errors
Volatile Errors
Volatile Warnings
Error reset: reset the appliance by switching off and on from the "FAST/ " knob (Fig. 8, Ref.A).
If the cause of the malfunction disappears immediately when reset, the appliance resumes its regular
operation. On the contrary, if the error code continues to appear on the display: contact the Technical
Service Center.
CODE DESCRIPTION
1 ERROR BAD DATA FLASH
9 ERROR CANT UNLOCK
11 ERROR NTC LOW OVERHEATING [OUTLET]
11 ERROR NTC HIGH OVERHEATING [OUTLET]
12 ERROR RELAY STUCK [OUTLET]
15 ERROR DRY HEATING [OUTLET]
21 ERROR NTC LOW OVERHEATING [INLET]
21 ERROR NTC HIGH OVERHEATING [INLET]
22 ERROR RELAY STUCK [INLET]
25 ERROR DRY HEATING [INLET]
10 ERROR NTC HIGH SHORTED[ OUTLET]
10 ERROR NTC HIGH OPEN [OUTLET]
10 ERROR NTC LOW SHORTED[ OUTLET]
10 ERROR NTC LOW OPEN [OUTLET]
20 ERROR NTC HIGH SHORTED [INLET]
20 ERROR NTC HIGH OPEN [INLET]
20 ERROR NTC LOW SHORTED [INLET]
20 ERROR NTC LOW OPEN [INLET]
14 ERROR LOW HEATING RATE [OUTLET]
24 ERROR LOW HEATING RATE [INLET]