INTRODUCTION

The purpose of this modification is to raise the humidity inside the XML300 to 50% Rh. This reduces
the STATIC MARKS, FILM CURL and FILM SEPARATION problems. The moistened air circulates
inside the XML300 cabinet. This increases the efficiency of the HUMIDIFIER.
BASIC FUNCTION:
HUMIDITY
SENSOR
If the humidity inside the XML300 is below 50% Rh, the FAN is switched on and draws air through
the moistened HUMIDIFIER FILTER CARTRIDGE. This air absorbs humidity from the FILTER.
When the humidity reaches the set level, PCB A16 switches off the FAN.
PCB A16 is also used with the ML700 HUMIDIFIER. The high voltage parts on it are only used with
the ML700 HUMIDIFIER. They are not used for the XML300 HUMIDIFIER.
The water level is controlled by the LEVEL SENSOR. If the water level is too low, the TWIN
WATER VALVE V1 is energised and the water reservoir is filled up. However the WATER VALVE
V1 can only be energised if the HUMIDITY is below the set level.