CAUTION!
The drain hose should not be submerged in water and should be securely xed and
leak-free.
Drain hose is not to be extended. If necessary contact Aftersales service.
11.5 Fresh water connection
Make sure that the gaskets are inserted.
1. Connect the water inlet hose with the angled end
to the appliance (Fig. 10.5-1). Tighten the screw
joint by hand.
2. The other end connect to a water tap with a 3/4
thread (Fig. 10.5-2).
Note: Aquastop system:
The models are equipped with an aquastop inlet hose.The aquastop system protects
against water damage by automatically cutting the fresh water supply in case of a leak-
ing hose. This is indicated by a red marker (A). The hose must be replaced.
10.6 Electrical Connection
Before each connection check if:
power supply, socket and fusing are appropriate to
the rating plate.
the power socket is earthed and no multi-plug or
extension.
the power plug and socket strictly match.
Put the plug into the socket (Fig. 10.6).
WARNING!
dry and leack free!
Take care these parts are never to be crushed, kinked, or twisted.
If the supply cord is damaged, it must be replaced by the service agent (see warranty
card) in order to avoid a hazard.
Note: Tub Clean
nance run programme "Tub Clean" with no load and small amount of detergent or with
special machine cleaner to remove possibly corruptive residues.