190
So lv ing Pr o ble m s
Message
Bad command or
file name
Bad error-
correction code
(ECC) on disk read
Controller has
failed
Data error
Decreasing
available memory
Diskette drive 0
seek failure
Diskette drive 1
seek failure
Diskette read
failure
Cause
The command for file
name you entered does not
exist or is not in the
pathname you specified.
The floppy drive or hard
drive controller detected
an uncorrectable read
error.
The hard drive or the
associated controller is
defective.
The floppy or hard drive
cannot read the data.
One or more dual in-line
memory modules
(DIMMs) may be faulty or
improperly seated.
A cable may be loose, or
the computer
configuration information
may not match the
hardware configuration.
A cable may be loose, or
the floppy may be faulty.
Action
Make sure you have spelled
the command correctly,
placed spaces in the proper
location, and used the
correct pathname.
See
"Floppy Drive
Problems" or
"Hard Drive
Problems."
See
"Floppy Drive
Problems" or
"Hard Drive
Problems."
Run the chkdsk utility in
the Microsoft Windows
operating system to check
the file structure of the
floppy or hard drive. See
your operating system
documentation for more
information.
If you are using another
operating system, run the
appropriate utility to check
the file structure of the
floppy or hard drive. See
your operating system
documentation.
See
"Computer Memory
Problems."
See
"Floppy Drive
Problems" or
"Hard Drive
Problems."
See
"Floppy Drive
Problems" or
"Hard Drive
Problems."