IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
The RUGGEDCOM RS400 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Dielectric Strength
RUGGEDCOM RS400
Installation Manual, 02/2020, C79000-G8976-1016-10
Test
Mains Frequen-
cy Voltage
Ripple on DC
Power Supply
Dielectric
Strength
H.V. Impulse
Description
ESD
Enclosure Contact
Radiated RFI
Enclosure Ports
Fast Transient
DC Power Ports
AC Power Ports
Earth Ground Ports
Oscillatory
DC Power Ports
AC Power Ports
DC Power Ports
AC Power Ports
HV Impulse
DC Power Ports
AC Power Ports
6.2 EMC and Environmental Type Tests
Description
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Air
Signal Ports
Signal Ports
1 kV Common and Differential Mode at 1 MHz
1 kV Common and Differential Mode at 1 MHz
Signal Ports
Signal Ports
Test Levels
2.5 kV common, 1 kV dif-
ferential mode at 1 MHz
2.5 kV common, 1 kV dif-
ferential mode at 1 MHz
30 V Continuous, 300 V for 1 s
30 V Continuous, 300 V for 1 s
10%
2 kVac (Fail-Safe Relay Output)
1.5 kVDC
2 kVAC
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV at 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV Common Mode at 1 MHz
2 kVAC
1.5 kVDC
2 kVAC
5 kV (Failsafe Relay)
5 kV
5 kV
Certification
Severi-
ty Lev-
els
3
3
4
4
3
 
 
 
 
 
 
37