Clearances to combustible construction
Any materials of a building structure or decorative structure made
of wood, compressed paper, plant fibres, vinyl/plastic or other
materials that are capable of transferring heat or being ignited
and burned. Such material shall be considered combustible even
though flame-proofed, fire-retardant treated or surface-painted,
or plastered.
Do not use this appliance under unprotected overhead
combustible surfaces.
Insulated jacket
If the side burner/griddle is to be placed into a combustible
enclosure, an approved insulated jacket is necessary. Insulated
jackets are available from your dealer. Use only the DCS insulated
jacket which has specifically been designed and tested for this
purpose. Review the detail drawing shown and take into account
the provisions shown for gas line connection clearance in the
right rear corner. It is required that ventilation holes are provided
in the enclosure to eliminate the potential build-up of gas in the
event of a gas leak. The supporting ledges or deck must be level
and flat and strong enough to support the side burner/griddle
and insulated jacket. The counter should also be level.
30" insulated jacket part number: 70859
7
CLEARANCES
b
CLEARANCE DIMENSIONS
A Minimum distance from combustible construction to rear of double side
burner/griddle (above counter)
B Minimum distance from combustible construction to sides of double side
burner/griddle (above counter)
a
GDSBE1-30 MODELS
INCHES
12
12
MM
305
305