CART LP CONNECTION
Units set for use with LP gas come equipped with a high capacity hose/regulator assembly
for connection to a standard 20 lb. LP cylinder (Type 1). The LP tank is not included. The
system is leak tested, do not remove the Regulator/Hose assembly from the product during
cart installation.
Connection: 1/2" NPT female with 3/8" flare adapter. Operating pressure: 11.0" W.C.
Supply pressure: 12" to 14" W.C
Connecting LP regulator/hose assembly to the tank/valve assembly
First, ensure the main valve on the tank is completely closed, all burner dials are in the
position and the cart is stable. Although the flow of gas is stopped when the Type 1 system is
disconnected as part of its safety feature, you should always turn off the LP tank main valve
after each use and during transport of the tank or unit.
Open the tank drawer of the cart and place the LP tank into the tank retention device (as
shown in the cart installation guide). Insert the regulator inlet into the tank valve and turn
the black coupler clockwise until it tightens. Do not over tighten the coupler. Turn the main
tank valve
and the burner control valves to
ON
system to purge. Turn valves
and wait 5 minutes before attempting to ignite the burners.
OFF
Threading compound must
be resistant to LP gas
type 1 regulator
main tank valve
to type 1 tank
Changing the LP cylinder
Ensure the main tank valve is turned off before turning the coupler counter clockwise, the
inlet will then disengage. Remove the inlet from the tank valve opening. Your local LP filling
station should be equipped with the proper equipment to fill your tank.
Do not attempt to remove, repair or replace the regulator/hose assembly. This must be
done by qualified and licensed technician only.
for about 20 seconds to allow the air in the
HI
base of product
1/2" female NPT
x 3/8 male flare
(installed on unit)
LP regulator hose
assembly 11" W.C.
(installed on unit)
GAS CONNECTION
If the double side burner/griddle is to be installed in a built-in application, then the side
burner/griddle must be installed in accordance with the built–in installation guidelines and
the LP regulator/hose assembly must be removed from the product.
When an LP unit is being directly connected to an LP house system, you must follow the
natural gas connection guidelines. The installer must provide the proper gas regulator to
reduce the gas pressure to 11" W.C.
Connection: LP Hose with a Type 1 quick disconnect and regulator. Operating pressure: 11.0"W.C.
To operate your built-in side burner/griddle on LP gas utilizing a 20lb type 1 cylinder, then a
OFF
built-in LP tank restraint must be installed prior to initial use of the side burner/griddle. The
Installer must supply ½" ID Flex hose and fixed pipe and a flare adaptor
adapter 3/8" flare
fitting 1/2" NPT female
LP regulator/
hose assembly
BUILT-IN LP CONNECTION
base of product
open top manifold
20lb LP tank*
Tank retention
device*
1/2" ID flex hose with 1/2"
NPT fittings*
1/2" NPT fixed pipe*
Enclosure wall
*not supplied
10