  • Page 1 POWER BURNER PBE1 Models INSTALLATION GUIDE US CA...
  • Page 2: Safety And Warnings

    SAFETY AND WARNINGS WARNING! Electric Shock Hazard Failure to follow this advice may result in electric shock or death. • This appliance is equipped with a three-prong or four-prong grounding plug for your protection against shock hazard and should be plugged DANGER directly into a properly grounded power outlet.
  • Page 3 SAFETY AND WARNINGS WARNING! WARNING! Hot Surface Hazard Explosion Hazard Failure to follow this advice may result in fire, Failure to follow this advice may result in injury burns, scalds or personal injury. or death • Accessible parts may become hot during use. •...
  • Page 4 SAFETY AND WARNINGS Do not store a full LP tank in direct sunlight. Gas requirements After a period of storage or non-use, the appliance should be checked for gas leaks, This appliance can be used with any brand of 20lb LP gas tank provided it is compatible deterioration, proper assembly, and burner obstructions before use.
  • Page 5: Product Dimensions

    PRODUCT DIMENSIONS FRONT PROFILE PBE1 MODELS PRODUCT DIMENSIONS INCHES A Overall height (excluding burners and pan supports) 10 1/2 B Overall width C Overall depth (excluding dials) 26 7/8 D Depth of chassis 22 1/2 E Width of chassis (including support brackets) 21 3/4 F Height below countertop 10 1/8...
  • Page 6: Built-In Construction

    BUILT-IN CONSTRUCTION As the power burner is designed for larger cookware, it is recommended that the product is mounted 6-12” below the countertop. Sufficient space should also be left around the product for safe cookware handling. RECESSED CUTOUT RECESSED INSULATED JACKET CUTOUT If the unit is to be placed into a combustible enclosure, an insulated jacket is required.
  • Page 7 BUILT-IN CONSTRUCTION As the power burner is designed for larger cookware, sufficient space should be left around the product for safe handling. COUNTER TOP LEVEL CUTOUT COUNTER TOP LEVEL INSULATED JACKET CUTOUT If the unit is to be placed into a combustible enclosure, an insulated jacket is required. ventilation ventilation PBE1 MODELS...
  • Page 8: Built-In Clearances

    BUILT-IN CLEARANCES Clearances to non-combustible construction Material which is not capable of being ignited and burned, such as materials consisting entirely of, or a combination of, steel, iron, brick tile, concrete, slate, and plaster. The power burner is designed for easy placement into built-in masonry enclosures.
  • Page 9 BUILT-IN CLEARANCES Clearances to combustible construction Any materials of a building structure or decorative structure made of wood, compressed paper, plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-retardant treated or surface-painted, or plastered.
  • Page 10 TRIVET ASSEMBLY MAIN TRIVET SMALL POT SUPPORT The main trivet assembly is made up of two halves that interlock to form the cooking surface. A small pot support is supplied with the Power Burner for cooking with pots smaller than 8”. To install the trivets, position the feet onto the products ledge and slot the trivets together.
  • Page 11: Electrical Connection

    ELECTRICAL CONNECTION All units are supplied with a 12V power transformer to operate the products ignition and dial illumination features. The transformer is sealed in a box with an attached power supply cord. Electrical requirements Use only a Ground Fault Interrupter (GFI) protected circuit with this product.
  • Page 12: Gas Requirements

    GAS CONNECTION GAS REQUIREMENTS NATURAL GAS CONNECTION Verify the type of gas supply to be used, either natural or LP, and make sure the marking Connection: 1/2” NPT male with 3/8” flare adapter Operating pressure: 4” W.C. on the appliance rating plate agrees with that of the supply. The rating plate is located Supply pressure: 5”...
  • Page 13: Leak Testing

    GAS CONNECTION BUILT-IN LP CONNECTION LEAK TESTING When an LP unit is being directly connected to an LP house system, you must follow the A complete gas tightness check must be performed at the installation site. Periodically natural gas connection guidelines. The installer must provide the proper gas regulator to check the whole system for leaks, or immediately if the smell of gas is present.
  • Page 14: Burner Adjustment

    BURNER ADJUSTMENT FLAME HEIGHT ADJUSTMENT LOW FLAME ADJUSTMENT Flames should be blue and stable with no yellow tips, excessive noise or lifting (Note: LP The valve for the outer burner feature an adjustable low setting. Due to fluctuations in gas units may have some yellow tipping).
  • Page 15: Installer Checklist

    INSTALLER CHECKLIST IMPORTANT! Read all installation instructions in this manual to see if the unit has been correctly installed. Ensure that installation has been completed correctly before use. Ensure that: specified clearances are maintained to combustibles flame has been checked and adjusted if required proper enclosure ventilation has been verified each burner lights satisfactorily - individually or with adjacent burner lit all internal packaging and any adhesive residue is removed...