Clearances to non-combustible construction
Material which is not capable of being ignited and burned, such as
materials consisting entirely of, or a combination of, steel, iron, brick
tile, concrete, slate, and plaster.
The side burner/griddle is designed for easy placement into built-
in masonry enclosures. For non-combustible applications the unit
drops into the opening and hangs from its side flanges. A deck is
not required to support it from the bottom.
Fisher & Paykel recommends installing the manual shut-off valve
in a location readily accessible by the customer, so that gas to the
appliance can be shut off in an emergency situation. However, the
appliance must not be modified in any way to accommodate such
placement.
A level should be used to ensure that the unit is level both front-
to-back and side-to-side. If it is not level, burner combustion may
be erratic or the unit may not function efficiently for grease flow.
CLEARANCES
b
CLEARANCE DIMENSIONS
A Minimum distance from non-combustible construction to rear of double
side burner/griddle (above the cook surface)
B Minimum distance from non-combustible construction to sides of double
side burner/griddle (above the cook surface)
a
GDSBE1-30 MODELS
INCHES
MM
3
76
6
152
6