SAFETY AND WARNINGS WARNING! Electric Shock Hazard Failure to follow this advice may result in electric shock or death. • This appliance is equipped with a three-prong or four-prong grounding plug for your protection against shock hazard and should be plugged DANGER directly into a properly grounded power outlet.
Page 3
SAFETY AND WARNINGS WARNING! WARNING! Hot Surface Hazard Explosion Hazard Failure to follow this advice may result in fire, Failure to follow this advice may result in injury burns, scalds or personal injury. or death • Accessible parts may become hot during use. •...
Page 4
SAFETY AND WARNINGS Do not store a full LP tank in direct sunlight. Gas requirements After a period of storage or non-use, the appliance should be checked for gas leaks, This appliance can be used with any brand of 20lb LP gas tank provided it is compatible deterioration, proper assembly, and burner obstructions before use.
PRODUCT DIMENSIONS FRONT PROFILE SBE1 MODELS PRODUCT DIMENSIONS INCHES A Overall height (excluding burners and pan supports) 10 5/8 B Overall width 14 11/16 C Overall depth (excluding dials) 26 7/8 D Depth of chassis 22 9/16 E Width of chassis (including support brackets) 11 7/8 F Height below countertop 9 15/16...
CUTOUT DIMENSIONS STANDARD CUTOUT The side burner can be installed into a combustible enclosure with zero clearance from the back, side and bottom below the counter top level. A minimum of 6” (152mm) from the back and sides must be maintained from the side burner above the cooking surface. ventilation SBE1 MODELS SBE1 MODELS...
ELECTRICAL CONNECTION All units are supplied with a 12V power transformer to operate the products ignition and dial illumination features. The transformer is sealed in a box with an attached power supply cord. Electrical requirements Use only a Ground Fault Interrupter (GFI) protected circuit with this product.
GAS CONNECTION GAS REQUIREMENTS NATURAL GAS CONNECTION Connection: 1/2” NPT male with 3/8” flare adapter Operating pressure: 4.0” W.C. Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating plate agrees with that of the supply. The rating plate is located on Supply pressure: 5”...
Page 9
GAS CONNECTION BUILT-IN LP CONNECTION adapter 3/8” flare base of product fitting 1/2” NPT female open top manifold When an LP unit is being directly connected to an LP house system, you must follow the natural gas connection guidelines. The installer must provide the proper gas regulator to LP regulator/ reduce the gas pressure to 11”...
LEAK TESTING LOW FLAME ADJUSTMENT A complete gas tightness check must be performed at the installation site. Periodically The valves on the side burner feature an adjustable low setting. Due to fluctuations in gas check the whole system for leaks, or immediately if the smell of gas is present. pressure, or heating value you may feel it necessary to increase or decrease gas flow in the low position.
INSTALLER CHECKLIST IMPORTANT! Read all installation instructions in this manual to see if the unit has been correctly installed. Ensure that installation has been completed correctly before use. Ensure that: specified clearances are maintained to combustibles flame has been check and adjusted if required proper enclosure ventilation has been verified each burner lights satisfactorily - individually or with adjacent burner lit all internal packaging and any adhesive residue is removed...