Leak Testing - Fisher & Paykel DCS GDSBE1-30 Installation Manual

Double side burner/griddle
Table of Contents

Advertisement

A complete gas tightness check must be performed at the installation site. Periodically check
the whole system for leaks, or immediately if the smell of gas is present.
Removing the valve panel
1
2
3
11

LEAK TESTING

Remove all dials by pulling outwards.
Remove the 2 screws securing
the valve panel to the unit using
a Phillips screwdriver.
Pull the valve panel down then
outward and unplug any wires.
Testing for leaks
1
leak points
leak points
NG:
2
leak points
LP:
If a leak is present
Immediately turn the gas supply
and tighten any leaking connections. Turn gas
OFF
and recheck. If you cannot stop a gas leak turn the gas supply
utility or the dealer you purchased the appliance from. Only parts recommended by the
manufacturer should be used on the side burner/griddle, substitution can void the warranty.
Prepare soap solution by combining
one part liquid detergent and one
part water. Pour into a spray bottle.
Ensure all control valves are in the
position before turning the gas
OFF
supply
.
ON
Check all connections from the
supply line or LP cylinder by
applying the solution around the
connection, tubing and end of the
manifold. Soap bubbles will appear
where a leak is present.
,
ON
and call your local gas
OFF

Advertisement

Table of Contents
loading

Table of Contents