4.2/5.0/6.0/7.1/8.0/9.0 kw class 15000 btu/h class removal procedure

Advertisement

Si04-855
Step
Unfasten the 2 hooks
7
on the lower side, and
then the 2 hooks on the
upper side.
Remove the control
PCB.
3. Remove the swing motor
for horizontal blades.
1
Remove the screw of
the swing motor.
Remove the swing
2
motor.
Removal Procedure
Procedure
Upper hook
Lower hook
[S35]
[S32]
Swing motor
Removal of Electrical Box / PCBs / Swing Motors
Control PCB
(R17129)
[S1]: fan motor
[S6]: swing motor (horizontal
blades)
[S1]
[S8]: swing motor (vertical
blades)
[S26]:buzzer PCB
[S28]:signal receiver PCB
[S32]:indoor heat exchanger
[S6]
[S35]:INTELLIGENT EYE
[S8]
[S26]
Some models have no
harness for [S8].
(R2697)
[S28]
Some models have no
INTELLIGENT EYE sensor
PCB or harness for [S35].
(R2787)
(R2788)
Points
thermistor
sensor PCB