Notes on connecting to the
mains water supply
Connection to the mains water sup‐
ply should only be carried out by a
qualified and competent person in
accordance with national and local
regulations.
Before plumbing the appliance in,
ensure that it is disconnected from
the mains electricity supply.
Turn off the water supply at the tap
before connecting the water intake
hose to the coffee machine.
IMPORTANT
Australia and New Zealand. This ap‐
pliance must be installed according
to AS/NZS 3500.1 and AS/NZS
3500.2. Backflow prevention is al‐
ready integrated in the appliance.
The water quality must conform to
the requirements for drinking water
in the country in which the appliance
is being installed.
This appliance meets the requirements
of IEC 61770 and ATS 5200.105.
All devices used for connecting the
appliance to the mains water supply
must comply with the current nation‐
al and local safety regulations in the
country in which the appliance is be‐
ing installed.

Mains water connection

The machine is only suitable for con‐
nection to a cold water line that
– is directly connected to the fresh wa‐
ter mains in order to ensure sufficient
circulation and therefore good water
quality.
Avoid connection to a water supply
in which the water might stagnate.
This will affect the taste of drinks
prepared with the coffee machine.
– The machine is constructed to com‐
ply with the relevant DIN standard
and may be connected to the mains
drinking water supply without a non-
return valve if national regulations
permit.
– The water inlet must be able to with‐
stand the required operating pres‐
sure.
– The water flow pressure needs to be
between 1 and 10 bar (10
Pa).
– The stainless steel hose supplied is
1.5 m long. The hose may not be
lengthened as too much water would
then remain in the hose, adversely af‐
fecting the quality of the coffee.
– National and local hygiene regula‐
tions must be complied with.
– A tap must be provided between the
stainless steel hose and the house‐
hold water supply to ensure that the
water supply can be cut off if neces‐
sary.
The tap should be easily accessible
after the machine has been built in.